site stats

Fitmore hip stem

Web18 yr old with L hip pain. What’s your go to stem for this? @freakhip 44 comments on LinkedIn WebSep 29, 2024 · The subjects consisted of patients who underwent total hip arthroplasty (THA) with a Fitmore or GTS stem (both stems are manufactured by Zimmer Biomet Holdings, Inc., Indiana, USA) (Fig. 1) at Sapporo Medical University Hospital between April 2016 and March 2024.With regard to the stem used, patients were randomly selected by …

Zimmer Hit with a Serious Hip Replacement Part Recall

WebJan 6, 2016 · The Fitmore Hip Stem (Zimmer, Winterthur, Switzerland) is a curved, uncemented triple-tapered stem made from titanium alloy. Proximally, it has a titanium vacuum plasma spray coating, while the … WebThe Zimmer femoral stems and necks are metal alloy implants used for hip replacements that allow the surgeon to fit the implant specifically to the patient. During hip replacement surgery, the damaged portions of the … st louis medical spa https://pisciotto.net

Cortical hypertrophy with a short, curved uncemented hip stem …

Web开馆时间:周一至周日7:00-22:30 周五 7:00-12:00; 我的图书馆 WebMar 21, 2011 · Description. The Zimmer Fitmore stem system is a curved, short (44 to 60 mm in length), uncemented femoral stem with a trapezoidal cross section and triple taper geometry, available since 2008. The device is manufactured from Zimmer’s Protasul™ titanium alloy, has a proximal Ti-plasma coating and is distally rough blasted. WebApr 1, 2014 · DOI: 10.1016/j.jocd.2013.11.001 Corpus ID: 2830715; Osseointegration of Fitmore stem in total hip arthroplasty. @article{Gasbarra2014OsseointegrationOF, title={Osseointegration of Fitmore stem in total hip arthroplasty.}, author={Elena Gasbarra and Monica Celi and Fabio Luigi Perrone and Riccardo Iundusi and Luigia Anna Di … st louis memphis prediction

Bone remodelling of the proximal femur after hip revision TCRM

Category:Fitmore® Hip Stem Manufacturing Process - Zimmer Biomet TV

Tags:Fitmore hip stem

Fitmore hip stem

Primary stability of the Fitmore stem: biomechanical comparison

WebJan 10, 2024 · A total of 241 hips in patients who received total hip arthroplasty (THA) using the Fitmore stem between Jan 2014 and Jun 2016 at the hospital were eligible for …

Fitmore hip stem

Did you know?

WebMay 27, 2024 · Background An increased occurrence of cortical hypertrophy (CH) was observed 1–2 years after implanting short curved Fitmore hip stems. There are no … WebApr 18, 2011 · Fitmore® Hip Stem Manufacturing Process . HCP Content Posted April 18, 2011 in Manufacturing Videos

WebJun 30, 2014 · Share on Social Media. Facebook. Twitter WebCorrespondence: Bernd Alexander Ishaque, Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, Giessen, 35392, Germany, Tel +49 641 98542914, Fax +49 641 98542969, Email [email protected]. Abstract: Short stem hip replacement has …

WebJun 24, 2024 · The Fitmore hip stem is an uncemented short curved hip stem available in four different offset options with a CCD-Angle ranging from 140 to 127° [A (140°), B (137°), B extended (129°) and C (127°)]. Every offset option is available in 14 different sizes. Allofit cup is a bi-hemispherical press fit cup with sizes ranging from 42 to 68 mm. WebThe aims of this study were to identify whether the bone mineral density (BMD) of the proximal femur increases following hip revision with a metaphyseal-fixation femoral stem and to identify the factors associated with BMD recovery. Methods: This was a retrospective study involving 36 patients who underwent hip arthroplasty with a metaphyseal ...

WebBackground/aim: Fitmore® hip stem belongs to the group of short stem prostheses with the metaphysar stabilization, with its shape and form that protects the bone mass in the …

WebEXAFIT Revision stem 9999 Fitmore Hip Stem 99 9 99 9999 FracSure Hip system 99 9 99 9999 Heritage stem (XX-8095-XXX-XX) 99 9 9 9 Intermedia stem 99999 Lamella stem 99999 ... Trabecular Metal Primary Hip Stem 99 99 999 Thompson monoblock stem VARIALL stem (except ALLOCLASSIC VARIALL SLV stem) 99999 VerSys Epoch RNL … st louis memphis schoolWebThe Fitmore Hip Stem's short length and curved design helps preserve the patient's natural bone in the greater trochanter, where it matters most. Zimmer Biomet has been at the … st louis meramec community collegeWebThe Fitmore® hip stem (Zimmer, Warsaw, Ind) is a bone-conserving stem designed for use in MIS techniques. The technique described here is a single-incision anterior approach with the Fitmore system using a special orthopedic table. MeSH terms Arthroplasty, Replacement, Hip / methods* Hip Joint / diagnostic imaging ... st louis men\u0027s basketball scheduleWebApr 18, 2011 · Fitmore® Hip Stem Manufacturing Process . HCP Content Posted April 18, 2011 in Manufacturing Videos st louis medical schoolWebThe Avenir Complete Hip System is compatible with ONE Planner Hip, a web-based preoperative planner for primary total hip arthroplasty. Using the auto-plan mode, surgeons can create a preoperative plan within five minutes. ONE Planner Hip features an optional spinopelvic mobility assessment tool if both a sitting and standing lateral x-ray are ... st louis men\u0027s health clinicWebExplore más de 120,000 registros de retiros, alertas y notificaciones de seguridad de dispositivos médicos y sus conexiones con los fabricantes. st louis metro reduced fare permitWebMay 27, 2024 · Background: An increased occurrence of cortical hypertrophy (CH) was observed 1-2 years after implanting short curved Fitmore hip stems. There are no published data about either the clinical relevance or the progression of CH over the long term. Methods: Ninety-six primary total hip arthroplasties were performed between 2008 and … st louis metro schedule pdf